danaxlit.blogg.se

Dsc alarm panel beeping
Dsc alarm panel beeping












dsc alarm panel beeping
  1. #Dsc alarm panel beeping code#
  2. #Dsc alarm panel beeping windows#

Upon arming, the Armed light and Bypass light will turn ON.

#Dsc alarm panel beeping code#

To arm the system in the Stay mode, either press and hold the Stay function button for 2 seconds or enter a valid user code and stay within the premises do NOT violate a door programmed as Delay.

#Dsc alarm panel beeping windows#

If the Ready light is OFF ensure all protected doors and windows are secure or bypassed. Stay Arming The Ready light must be ON to arm the system. If the Audible Exit Delay option is enabled, the keypad will beep once every second during the exit delay, and three times a second during the last 10 seconds to alert the user to leave. If a user code was used to arm the system and Stay/Away zones are programmed, the Bypass light will turn ON and will turn OFF when a door programmed as Delay is violated. Upon arming, the Armed light will turn ON. To arm the system in the Away mode, either press and hold the Away function button for 2 seconds or enter a valid user code and leave the premises through a door programmed with entry delay. If the Ready light is OFF, ensure all protected doors and windows are secure or bypassed. To stop your alarm from beeping, press after pressing to diagnose your trouble.Īway Arming The Ready light must be ON to arm the system.

dsc alarm panel beeping

To set your time and date, press followed by the time in military format ie. Trouble Loss of Time – This trouble will appear when the time and date need to be set on your system. Press to view which wireless zone has the device low battery, once you view which zone has the low battery you may replace it, or call safetech technical support for further assistance. Trouble Device Low Battery – This trouble will only be generated when a Wireless device on the system has a Low Battery. Once you have verified the zone, check to see if the contact has been physically tampered with, if everything appears normal, contact SafeTech technical support for further assistance. Trouble Zone Tamper – This trouble will only be generated when a tamper condition is detected on a zone in your system. Once you know which zone number is in trouble, check that the physical contact has not been tampered with for the particular zone, if everything appears to be normal, contact SafeTech technical support. Press on the Keypad, and it will indicate what zone is in trouble.

dsc alarm panel beeping

Trouble Zone Fault – This trouble indicates if any zone on the system is currently in a trouble condition. Perform all the steps for Trouble, if the trouble persists, please contact SafeTech technical support. This trouble may appear in conjunction with Trouble. The system will attempt a number of times to send a signal, after all attempts have failed to reach the central station, it will display this trouble. Trouble Failure to Communicate (FTC) – This trouble is generated when a signal transmissions fails to reach the central station. If this trouble is present, make sure you have a dial tone on your phone line, ensure that your phone company is not working on the phone lines, as well as making sure no other devices are tying up the line like a fax machine, or DSL modem. Trouble Telephone Line Trouble – The telephone connection to the control unit is constantly being monitored to ensure your phone line is not being tampered with. If the problem persist, contact technical support for further assistance. You can check that the transformer has not been unplugged, or that any service is being done to the power in your area. Trouble AC Failure – This trouble indicates that AC power is no longer being supplied to your system. If another number shows on your keypad, please contact Safetech Technical Support. If light 1stays on, it indicates you have a low battery condition, and need to replace your system battery. To determine what trouble you have press again to view the specific trouble. Trouble Service Required – This light will be on if any of the following trouble conditions are detected on the panel: Low Battery, Bell Circuit, System Trouble, System Tamper, System Supervisory. Below is a detailed list of all possible troubles on your system. Trouble Light With Keypad BeepingTo view the trouble press and make note of which zone light comes on.














Dsc alarm panel beeping